Service · Leak detection, vacuum and recharge
Fridge Regas
Refrigerant top-ups done properly: leak found and repaired, system evacuated, then charged by weight.
A fridge that needs gas every few months has a leak. Topping it up without finding the leak wastes money and slowly damages the compressor, so we pressure test, repair, then evacuate and charge the system correctly.
We handle domestic fridges, display fridges, under-bar units, bottle coolers and cold room systems, with the correct refrigerant for each unit.
What we cover
- Domestic and commercial fridge regas
- Display and bottle cooler regas
- Cold room and freezer recharges
- Leak repair and pipe replacement
- Filter drier replacement
How it is done
Leak first
Pressure testing and electronic detection before any gas goes in.
Deep vacuum
Moisture and air removed so the charge stays stable.
Charged by weight
Refrigerant measured to the manufacturer's specification.
Correct gas
R134a, R404A, R407C, R410A and R22 replacements handled to spec.
Other services
Household Air Conditioning
Split and multi-split air conditioning supplied, installed and serviced for houses, townhouses and home offices.
Cold Room Installation
New cold rooms designed, panel-built, piped and commissioned for butchers, spaza suppliers, restaurants and farms.
Cold Room Maintenance
Scheduled servicing, fault finding and repair that keeps cold rooms holding temperature and stock safe.
Direct line
Temperature dropping? Let's look at it.